30 kVA / 35 kVA /40 kVA / 45 kVA
Compact Design
Mahindra Powerol diesel gensets have the capability to switch seamlessly to backup power due to its compact design & swift recovery. Also, voltage fluctuations are never an issue as our effective governing system controls ensure complete safety of your equipment.
Large Fuel Tank
With one of the most popular engines in its category, the Mahindra Powerol Engine fitted in this genset, it has one of the smallest footprints with high capacity fuel tanks in comparison to other gensets. It also has minimum vibrations and is very stable.
Longer Engine Life
All the stringent noise & emission norms stipulated by the Central Pollution Control Board of India (CPCB) are strictly followed by all Powerol DG Sets. All our engines are regularly tested on various applications for efficiency and performance in accordance to our promise of quality of the highest order.
Low Maintenance Cost
With the might of the whole Mahindra machinery at our disposal, our gensets come equipped with an Annual Maintenance Contract (AMC) and are the most fuel efficient in their class along with having very low operational costs. Our main USP is that we offer Zero-Leak engines with manual as well as AMF Control Panel Options available.
Preferred By All
Our gensets find application in industries like Telecom, Defence & the Railway Sector as well as Petrol Pumps, Hospitals, Super Markets, Banks & Construction Sites. Our presence in myriad applications speaks volumes about the quality of our products and the efficiency with which we deliver.
Assurance
- Over 400 sales and service touch points.
- Easy Finance schemes available.
- Fuel Efficient Engines.
Technical Specifications
- PARAMETERS DG Models
- Duty (Standby/ Prime) PrimeStand By
- 50 HZ PRIME-Rating(kVA) 30 kVA 30 kVA
- 50 HZ PRIME-Rated(kWe) 24 24
- 50 HZ PRIME-Rating(kVA) 3445TCIGM-C2 3445TCIGM-C2
- No of Phases 1/31/3
- No of Cylinders 33
- Output Voltage (V) 230V/415V 230V/415V
- Current (A) (1Phase / 3Phase) 130.4/ 41.7130.4/ 41.7
- Power Factor (lagging)0.80.8
- Frequency (Hz)/ RPM 50/150050/1500
- Governing classA1A1
- Starting system 12 V DC Elec 12 V DC Elec
- Fuel tank capacity 115115
- Genset Dimension (LxWxH $$) (mm) Approx. 3 Phase :- 2000 X 980 X 1280 1 Phase :- 2200 X 980 X 1280 3 Phase :- 2000 X 980 X 1280 1 Phase :- 2200 X 980 X 1280
- Genset Weight (kg) approx. 3 Phase :- 935 1 Phase:- 10263 Phase :- 935 1 Phase:- 1026
- Make Mahindra Mahindra
- Power Output# (HP) 44 38.6
- Aspiration Turbocharged & Intercooled Turbocharged
- No of Cylinders 3 3
- Bore x Stroke (mm) 88.9 X 110 88.9 X 120
- Displacement (cc) 2048 2235
- Fuel consumption @ 75% load (lit/hr) ^ 5.7 –
- Fuel consumption @ 100% load (lit/hr) ^ 7.3 –
- Lube oil specification SAE15W40 CI4 SAE15W40 CI4
- Total Lube Oil capacity (lit) 7 7
- Lube Oil Consumtion (lit/hr) $ 0.15% of Fuel Consumption 0.15% of Fuel Consumption
- Lube oil change period (hrs.) 300 hrs. for Oil Top Up 600 hrs. for Oil change 300 hrs. for Oil Top Up 600 hrs. for Oil change
- Radiator coolant capacity (liter) 9.5 9.5
- AlternatorDG Models
- Make CG/LS
- Enclosure Type IP23
- Voltage regulation +/- 1%
- Class of insulation Class H
- Maximum Unbalanced Load across Phases 25%
- PARAMETERS DG Models
- Duty (Standby/ Prime) Stand By
- 50 HZ PRIME :-
- Rating(kVA) 35 kVA
- Rated(kWe) 35
- Rating(kVA) 3445 TCIGM-C2
- No of Phases 1/3
- No of Cylinders 3
- Output Voltage (V) 230V/415V
- Current (A) (1Phase / 3Phase) 152.2 / 48.7
- Power Factor (lagging) 0.8
- Frequency (Hz)/ RPM 50/1500
- Governing class A1
- Starting system 12 V DC Elec
- Fuel Tank Capacity (lits) 115
- Genset Dimension (LxWxH $$) (mm) Approx. 3 Phase :- 2000 X 980 X 1280 1 Phase :- 2200 X 980 X 1280
- Genset Weight (Kg), Appx 3 Phase :- 926 1 Phase :- 984
- Make Mahindra
- Power Output# (HP) 44
- Aspiration Turbocharged & Intercooled
- No of Cylinders 3
- Bore x Stroke (mm) 88.9 X 110
- Displacement (cc) 2048
- Fuel consumption @ 75% load (lit/hr) ^ –
- Fuel consumption @ 100% load (lit/hr) ^ –
- Lube oil specification SAE15W40 CI4
- Total Lube Oil capacity (lit) 7
- Lube Oil Consumtion (lit/hr) $ 0.15% of Fuel Consumption
- Lube oil change period (hrs.) 300 hrs. for Oil Top Up 600 hrs. for Oil change
- Radiator coolant capacity (liter) 9.5
- AlternatorDG Models
- Enclosure Type CG/LS
- Enclosure Type IP23
- Voltage regulation +/- 1%
- Class of insulation Class H
- Maximum Unbalanced Load across Phases 25%
- PARAMETERS DG Models
- Duty (Standby/ Prime) Prime
- 50 HZ PRIME :-
- Rating(kVA) 40 kVA
- Rated(kWe) 32
- Rating(kVA) 4575 TCIGM-C2
- No of Phases 1/3
- No of Cylinders 4
- Output Voltage (V) 230V/415V
- Current (A) (1Phase / 3Phase) 173.9 / 55.7
- Power Factor (lagging) 0.8
- Frequency (Hz)/ RPM 50/1500
- Governing class A1
- Starting system 12 V DC Elec
- Fuel Tank Capacity (lits) 115
- Genset Dimension (LxWxH $$) (mm) Approx. 3 Phase :- 2000 X 980 X 1280 1 Phase :- 2200 X 980 X 1280
- Genset Weight (Kg), Appx 3 Phase :- 985 1 Phase :- 1051
- Make Mahindra
- Power Output# (HP) 57
- Aspiration Turbocharged & Intercooled
- No of Cylinders 4
- Bore x Stroke (mm) 88.9 X 110
- Displacement (cc) 2731
- Fuel consumption @ 75% load (lit/hr) ^ 7.3
- Fuel consumption @ 100% load (lit/hr) ^ 9.9
- Lube oil specification SAE15W40 CI4
- Total Lube Oil capacity (lit) 10.5
- Lube Oil Consumtion (lit/hr) $ 0.15% of Fuel Consumption
- Lube oil change period (hrs.) 300 hrs. for Oil Top Up 600 hrs. for Oil change
- Radiator coolant capacity (liter) 9.5
- AlternatorDG Models
- Enclosure Type CG/LS
- Enclosure Type IP23
- Voltage regulation +/- 1%
- Class of insulation Class H
- Maximum Unbalanced Load across Phases 25%
- PARAMETERS DG Models
- Duty (Standby/ Prime) Prime
- 50 HZ PRIME-Rating(kVA) 45 kVA
- 50 HZ PRIME-Rated(kWe) 32
- 50 HZ PRIME-Rating(kVA) 4575 TCIGM-C2
- No of Phases 1/3
- No of Cylinders 4
- Output Voltage (V) 230V/415V
- Current (A) (1Phase / 3Phase) 195.7/62.6
- Power Factor (lagging) 0.8
- Frequency (Hz)/ RPM 50/1500
- Governing class G2
- Starting system 12 V DC Elec
- Fuel Tank Capacity (lits) 115
- Genset Dimension (LxWxH $$) (mm) Approx. 3 Phase :- 2000 X 980 X 1280 1 Phase :- 2200 X 980 X 1280
- Genset Weight (Kg), Appx 3 Phase :- 996 1 Phase :- 1120
- Make Mahindra
- Power Output# (HP) 57
- Aspiration Turbocharged & Intercooled
- No of Cylinders (88.9 X 110) 4
- Displacement (cc) 2731
- Fuel consumption @ 75% load (lit/hr) ^ –
- Fuel consumption @ 100% load (lit/hr) ^ –
- Lube oil specification SAE15W40 CI4
- Total Lube Oil capacity (lit) 10.5
- Lube Oil Consumtion (lit/hr) $ 0.15% of Fuel Consumption
- Lube oil change period (hrs.) 300 hrs. for Oil Top Up 600 hrs. for Oil change
- Radiator coolant capacity (liter) 9.5
- AlternatorDG Models
- Enclosure Type CG/LS
- Enclosure Type IP23
- Voltage regulation +/- 1%
- Class of insulation Class H
- Maximum Unbalanced Load across Phases 25%